SIKA Themometers



 
SIKA Calibration Equipment                                                
Measuring, Control and Monitoring Instruments, Controllers
1 Digital Electronic Controller, Series THP,TLK,TDH,TDF
 
   
2 Electronic Measuring Device
   
   
3 Temperature Measuring Instrument, TS 31000
   
   
4 Measured Data Acquisition and Monitoring Systems
   
   
 

Optimal devices for every application

Electronic controllers, series THP, TDH, TDF are mostly used for control of temperature, pressure and humidity.

Programmable sensor inputs
The programmable sensor input allows for direct connection of temperature probes ( RTD, TC ) or normalized analog signals ( 0/1..5V, 0/2..10V, 0/4..20 mA ) for different signal sensors ( e.g. pressure sensors, humidity sensors... )

Control modes / alarm outputs
The controllers are available with PID, 2-point or 3-point control and 3-point motor valve control.
Up to 5 outputs as relais, SSR or norm signal are available.
Manifold alarm functions are programmable, e.g. it is possible to adjust the hysteresis, alarm output activity, start up behaviour and alarm LATCH.

 

top
 

 

THP 94

Autotuned, digital controller for temperature and process values
PID; 2-point or 3-point control
3-point motor valve control

Measuring inputs: 1
- Resistance thermometer: Pt 100 / 3-wire
- Thermocouples: J, K, R, S, T, B, E, N, L, U
- Norm signals:
0(4) ... 20 mA,
0(1) ... 5 V,
0(2) ... 10 V

Outputs: max. 5, up to 2 x contr. output
resp. 4 x alarm outputs possible
- Relay: change over contact:
6A / 2,25 A / 250 VAC
- Solid state relay ( SSR drive ):
24 VDC / 25 mA
- Norm signals: (as control outputs)
0(4) ... 20 mA,
0(2) ... 10 V


top
     
 

THP 98

Autotuned, digital controller for temperature values
PID; 2-point or 3-point control

Measuring inputs: 1
- Resistance thermometer: Pt 100 / 3-wire
- Thermocouples: J, K, R, S, T

Outputs: max. 5, up to 2 x contr. output
resp. 3 x alarm outputs possible
- Relay: change over contact:
6A / 2,25 A / 250 VAC
- Solid state relay ( SSR drive ):
24 VDC / 25 mA

top
     
 

THP 84

Autotuned, digital controller for temperature and process values
PID; 2-point or 3-point control
3-point motor valve control

Measuring inputs: 1
- Resistance thermometer: Pt 100 / 3-wire
- Thermocouples: J, K, R, S, T, B, E, N, L, U
- Norm signals:
0(4) ... 20 mA,
0(1) ... 5 V,
0(2) ... 10 V

Outputs: max. 2, up to 2 x contr. output
resp. alarm outputs possible
- Relay: close contact:
6A / 2,25 A / 250 VAC
- Solid state relay ( SSR drive ):
24 VDC / 25 mA
- Norm signals: ( as control outputs )
0(4) ... 20 mA,
0(2) ... 10 V

top
     
 

TLK 43 / TLK 42

Autotuned, digital controller for temperature and process values
PID; 2-point or 3-point control
3-point motor valve control (TLK 43 opt.)

Measuring inputs: 1
free programmable multi input
- Resistance thermometer: Pt 100 / 3-wire
- Semi conductor:
PTC: KTY 81 - 121 / 2-wire
NTC: 103 AT-2 / 2-wire
- Thermocouples: J, K, S
- Norm signals:
0(4) ... 20 mA,
0(1) ... 5V,
0(2) ... 10 V

Outputs: max. 4, up to 2 x contr. output
resp. 3 x alarm outputs possible
- Relay, close contact
4A / 2 A / 250 VAC
- Solid state relay ( SSR drive ):
14 VDC / 20 mA
- Norm signals: (as control outputs)
0(4) ... 20 mA,
0(2) ... 10 V (TLK 43 opt.)

top
     
 

TLK 41

Autotuned, digital controller for temperature and process values
PID; 2-point or 3-point control

Measuring inputs: 1
free programmable multi input
- Resistance thermometer: Pt 100 / 3-wire
- Semi conductor:
PTC: KTY 81 - 121 / 2-wire
NTC: 103 AT-2 / 2-wire
- Thermocouples: J, K, S
- Norm signals:
0(4) ... 20 mA,
0(1) ... 5V,
0(2) ... 10 V

Outputs: max. 4, up to 2 x contr. output
resp. 3 x alarm outputs possible
- Relay, close contact
4A / 2 A / 250 VAC
- Solid state relay ( SSR drive ):
14 VDC / 20 mA

top
     
 

THP 96

Autotuned, digital controller for temperature and process values
PID; 2-point or 3-point control

Measuring inputs: 1
- Resistance thermometer: Pt 100, Ni 100 / 3-wire
- Semi conductor PTC: KTY 81-121 / 2-wire
- Thermocouples: J, K, S
- Norm signals:
0 ... 20 mA,
4 ... 20 mA,
0 ... 10 V

Outputs: max. 2, up to 2 x contr. output
resp. alarm outputs possible
- Relay: change over contact:
8A / 3 A / 250 VAC
- Solid state relay ( SSR drive ):
12 VDC / 25 mA

top
     
 

THP 72
Autotuned, digital controller for temperature and process values
PID; 2-point or 3-point control

Measuring inputs: 1
- Resistance thermometer: Pt 100, Ni 100 / 3-wire
- Semi conductor PTC: KTY 81-121 / 2-wire
- Thermocouples: J, K, S
- Norm signals:
0 ... 20 mA,
4 ... 20 mA,
0 ... 10 V

Outputs: max. 2, up to 2 x contr. output
resp. alarm outputs possible
- Relay: change over contact,
8A / 3 A / 250 VAC
- Solid state relay ( SSR drive ):
12 VDC / 25 mA

top
     
 

THP 48

Autotuned, digital controller for temperature and process values
PID; 2-point or 3-point control

Measuring inputs: 1
- Resistance thermometer: Pt 100, Ni 100 / 3-wire
- Semi conductor PTC: KTY 81-121 / 2-wire
- Thermocouples: J, K, S
- Norm signals:
0 ... 20 mA,
4 ... 20 mA,
0 ... 10 V

Outputs: max. 2, up to 2 x contr. output
resp. alarm outputs possible
- Relay: change over contact:
8A / 3 A / 250 VAC
- Solid state relay ( SSR drive ):
12 VDC / 25 mA

top
     
 

THP 24

Autotuned, digital controller for temperature and process values
PID; 2-point or 3-point control

Measuring inputs: 1
- Resistance thermpmeter: Pt 100, Ni 100 / 3-wire
- Semi conductor PTC: KTY 81-121 / 2-wire
- Thermocouples: J, K, S
- Norm signals:
0 ... 20 mA,
4 ... 20 mA,
0 ... 10 V

Outputs: max. 2, up to 2 x contr. output
resp. alarm outputs possible
- Relay: close contact:
8A / 3 A / 250 VAC
- Solid state relay ( SSR drive ):
6 VDC / 25 mA

top
     
 

THP 35

Autotuned, digital controller for temperature and process values
PID; 2-point or 3-point control

Measuring inputs: 1
- Resistance thermometer: Pt 100, Ni 100 / 3-wire
- Semi conductor PTC: KTY 81-121 / 2-wire
- Thermocouples: J, K, S
- Norm signals:
0 ... 20 mA,
4 ... 20 mA,
0 ... 10 V

Outputs: max. 2, up to 2 x contr. output
resp. alarm outputs possible
- Relay: change over contact:
8A / 3 A / 250 VAC
- Solid state relay ( SSR drive ):
12 VDC / 25 mA

top
     
 

TDH 02

Autotuned, digital controller for temperature and process values
PID; 2-point or 3-point control

Measuring inputs: 1
- Resistance thermometer: Pt 100, Ni 100 / 3-wire
- Semi conductor PTC: KTY 81-121 / 2-wire
- Thermocouples: J, K, S
- Norm signals:
0 ... 20 mA,
4 ... 20 mA,
0 ... 10 V

Outputs: max. 2, up to 2 x contr. output
resp. alarm outputs possible
- Relay: change over contact:
8A / 3 A / 250 VAC
- Solid state relay ( SSR drive ):
12 VDC / 25 mA

top
     
   

TCPDE

Analog contoller for temperature value
PID or 2-point control

Measuring inputs: 1
- Resistance thermometer: Pt 100 / 3-wire
- Thermocouples: J, K

Outputs: 1 x relay:
- change over contact: 8 A / 3 A / 250 VAC

top
     
 

TDF 11

Digital controller for temperature values
2-point control

Measuring inputs: 1
- Semi conductor PTC: KTY 81-121 / 2-wire

Outputs: 1 x relay: change over contact,
8A / 3 A / 250 VAC

Displays: 1 line, 2 1/2-digits, 7-seg. LED
- Process value: red, 20 mm high

top
     
   

TDL 61

Digital controller for temperature values
2-point control

Measuring inputs: 1
- Semi conductor NTC: 103 AT-2 / 2-wire

Outputs: 1 x relay:
- change over contact: 8 A / 3 A / 250 VAC
- change over contact: 16 A / 6 A / 250 VAC (opt.)

top
     
   

TDL 51

Digital controller for temperature values
2-point control

Measuring inputs: 1
- Semi conductor NTC: 103 AT-2 / 2-wire

Outputs: 1 x relay:
- change over contact: 8 A / 3 A / 250 VAC
- change over contact: 16 A / 6 A / 250 VAC (opt.)

top
     
 

Electronic measuring device with manual selector switch
Series TS 9000 TM

Series TS 9000 TM units are used wherever a large number of measuring channels ( sensors ) have to be scanned with a measuring unit.
The instruments can be used with resistance thermometers, standard thermocouples and standard signals.
The 3 1/2-digit display is 11 or 20 mm high. The measuring channels are selected via keys or rotary switches.

top
     
 

Electronic measuring device with / without monitoring function
Series TS 9000

The series TS 9000 with it's modular construction can be used for a wide variety of measuring and monitoring functions.
The instruments are equipped with an input circuit for either the direct connection of resistance thermometers, thermocouples or a voltage / current input.
The 3 1/2-digit display can be supplied 11 or 20 mm high, depending on the housing size

top
     
 

TS 31000
Temperature measuring instrument with contacless operable selector switch

- 16 or 32 inputs for thermocouples type K, E, J, T, S, B or R

- type of thermocouple selectable by the user at the spot

- high-contrast 4-digit LED display easy to read even from a greater distance

- 2-line alphanumeric LCD text display

- contactless operation: selection of the measuring point and programming via 2 light reflecting buttons

- pre-configurable at works for up to 16 different applications, e.g. engine types

top
     
 

SIKA measured data acquisition and monitoring systems
TS 6700 TA and TS 16700 TA series

Unbroken monitoring!

Series TS 6700 TA measured data monitoring systems monitor process variables in machines, systems and process technology and detect when they cross threshold values.
The multi-channel measurement module of the monitoring unit allows resistance thermometers and thermoelementes to be connected directly, or any sensor with a standard signal output. This means that the system can be used for monitoring virtually all physical variables.

top
     
 

Measured data acquisition and monitoring systems
TS 6700 TA

sensor inputs
- Resistance thermometer
- Thermoelementes
- Standard signals

Measuring point
- 2-position, 7-segemnt, red, 11 mm high

Measured value
- 3 1/2-position, 7-segment, red, 11 mm high

Alarms 1-3
- In each case 2-position, 7-segment, red, 11 mm high
- Multiple alarms are displayed by the corresponding
display flashing

Measurement ranges and resolution
- -199,9...+199,9 °C / 0,1 K or +200...+1790 °C
( automatic range selection )

Measurement rate
- 7 measurements per second

top
     
 

Measured data acquisition and monitoring systems
TS 16700 TA

sensor inputs
- Thermoelements

Measuring point
- 2-position, 7-segemnt, red, 11 mm high

Measured value
- 3 1/2-position, 7-segment, red, 11 mm high

Alarms 1-3
- In each case 2-position, 7-segment, red, 11 mm high
- Multiple alarms are displayed by the corresponding
display flashing

Measurement ranges and resolution
- -199,9...+199,9 °C / 0,1 K or +200...+1790 °C
( automatic range selection )

Measurement rate
- 7 measurements per second

top
       

Home