SIKA Kombitemp
Dual temperature control with only one measuring point
The combination of electronic sensor and local display has many advantages:
- Temperature control with two measuring systems
independant of each other
- The Kombitemp offers increased security in accuracy
of measurement because it is possible to verify the
results of the electrical measurement against that
of the industrial thermometer and vice versa
- The installation costs of the instrument are reduced
because only one measuring point needs to be
installed for the electronic and local measurement.
- The operating reliability of the controlled system is
increased by the use of of the SIKA Kombitemp®
because defective electrical sensors or industrial
thermometers can be detected immediately.
- Both the electrical and the industrial thermometer are
DIN parts and can therefore be easily changed.
- The locally mounted thermometers can be used to
make adjustments at the temperature sensing point
and eliminate constant recourse of the remote
indication during setting up
|
 |
|
|
|
|
|
|
SIKA Kombitemp, angle 90°
Casing size 110 x 30 mm
A combined Industrial Therometer and electrical temperature sensor.
Ranges between -30°C and +200°C
Type K 130
- One point of measuring for both remote
and local temperature monitoring /
indication
- Based on an approved SIKA - Industrial
Thermometer
- Glass inserts and sensor elements
can easily be changed
|
 |
|
|
|
|
|
|
SIKA Kombitemp, angle 90°
Casing size 150 x 36 mm
A combined Industrial Therometer and electrical temperature sensor.
Ranges between -30°C and +200°C
Type K 610 ( adjustable coupling )
Type K 620 ( fixed thread connection )
- One point of measuring for both remote
and local temperature monitoring /
indication
- Based on an approved SIKA - Industrial
Thermometer
- Standard inserts for resistance
thermometers or thermocouples
- Standard immersion tubes
- Glass inserts and sensor elements
can easily be changed
- Optional with head-transmitter 4-20 mA |
 |
|
|
|
|
|
|
SIKA Kombitemp, angle 90°C
Casing size 150 x 36 mm
( without connection head )
A combined Industrial Therometer and electrical temperature sensor.
Ranges between -60°C and +200°C
Type K 510 ( adjustable coupling )
Type K 520 ( fixed thread connection )
- One point of measuring for both remote
and local temperature monitoring /
indication
- Based on an approved SIKA - Industrial
Thermometer
- Standard immersion tubes
- Glass inserts and sensor elements
can easily be changed
- Optional with head-transmitter 4-20 mA |
 |
|
|
|
|
|
|
SIKA Kombitemp, angle 90°
Casing size 150 x 36 mm
A combined Industrial Therometer and electrical temperature sensor.
Ranges between -60°C and +600°C
Type K 515 ( adjustable coupling )
Type K 525 ( fixed thread connection )
- One point of measuring for both remote
and local temperature monitoring /
indication
- with 2 m shielded cable
- Based on an approved SIKA - Industrial
Thermometer
- Glass inserts and sensor elements
can easily be changed as an unit |
 |
|
|
|
|
|
|
SIKA Kombitemp, straight
Casing size 110 x 30 mm
( without connection head )
A combined Industrial Therometer and electrical temperature sensor.
Ranges between -30°C and +200°C
Type K 110 ( adjustable coupling )
Type K 120 ( fixed thread connection )
- One point of measuring for both remote
and local temperature monitoring /
indication
- Based on an approved SIKA - Industrial
Thermometer
- Standard inserts for resistance
thermometers or thermocouples
- Standard immersion tubes
- Glass inserts and sensor elements
can easily be changed
- Optional with head-transmitter 4-20 mA |
 |
|
|
|
|
|
|
SIKA Kombitemp, straight
Casing size 150 x 36 mm
( without connection head )
A combined Industrial Therometer and electrical temperature sensor.
Ranges between -60°C and +600°C
Type K 410 ( adjustable coupling )
Type K 420 ( fixed thread connection )
- One point of measuring for both remote
and local temperature monitoring /
indication
- Based on an approved SIKA - Industrial
Thermometer
- Standard inserts for resistance
thermometers or thermocouples
- Standard immersion tubes
- Glass inserts and sensor elements
can easily be changed
- Optional with head-transmitter 4-20 mA |
 |
|
|
|
|
|
|
SIKA Kombitemp, straight
Casing size 110 x 30 mm
( without connection head )
with Protection Tube form D acc. to DIN 43763
A combined Industrial Therometer and electrical temperature sensor.
Ranges between -60°C and +400°C
Type K 430 ( fixed thread connection )
- For high pressure
- One point of measuring for both remote
and local temperature monitoring /
indication
- Standard immersion tubes
- Glass inserts and sensor elements
can easily be changed
- Optional with head-transmitter 4-20 mA |
 |
|
|
|
|
|
|
SIKA Kombitemp,
A combined Industrial Therometer and electrical temperature sensor.
Ranges between -30°C and +200°C
Type K 124
Type K 424
Type K 524
- One point of measuring for both remote
and local temperature monitoring /
indication
- Based on an approved SIKA - Industrial
Thermometer
- With 2 m shielded cable
- Fixed threat connection |
 |
|
|
|
|
|
|
SIKA Kombitemp, with plug
A combined Industrial Therometer and electrical temperature sensor.
Ranges between -30°C and +200°C
Type K 122
Type K 422
Type K 522
- Fixed thread connection
- One point of measuring for both remote
and local temperature monitoring /
indication
- Based on an approved SIKA - Industrial
Thermometer
- Standard immersion tubes
- Glass inserts and sensor elements
can easily be changed |
 |
|
|
|
|
|
|
Temperature Transmitter for Connection Head Form B
Type LKM
- Input:
thermocouple elements
( Type LKM 101 )
Pt 100 ( Type LKM 103 )
- Output signal 4-20 mA, 2-wire
- For installation in connection
head form B according to DIN
- High accuracy
- Insert in Ex-range
- Casing plastic Polyurethan |
 |
| |
|
|
|