Hand held instruments for humidity, temperature, pressure
Handy - Reliable - Precise
Digital measurement instrument for a wide range of applications
The handy and reliable instruments of the MH series are used for measurement and recording of humidity, temperature or pressure. The MH series is very flexible and is suitable for both, simple measurements and special applications.
Sensors
High-performance sensors with electronic linearization of the characteristic provide high assuracy during signal recognition and processing. matching sensors are available for extensive measurement jobs. |
 |
|
|
|
|
|
|
MH 3310
Digital hand held instrument for air humidity and temperature
Plug-in sensors
Measurement inputs:
(mini-DIN socket)
- Air humidity: capacitive sensor
- Temperature: Pt 1000 / 2 wire
Measurment range / resolution:
- Air humidity: 0.0 ... 100% rh / 0.1% rH
- Temperature: -40.0 ... 120.0°C / 0.1°C
Accuracy:
- Air humidity: ± 0.1% FS ± 1 digit
- Temperature: ± 0.2% FS ± 1 digit |
 |
|
|
|
|
|
|
MH 3330
Digital hand held instrument for air humidity and temperature
Plug-in sensors
Measurement inputs:
(mini-DIN socket)
- Air humidity: capacitive sensor
- Temperature: Pt 1000 / 2 wire
- Surface temp: Type K (NiCr-Ni)
Measurement range / resolution:
- Air humidity: 0.0 ... 100% rH / 0.1% rH
- Temperature: -40.0 ... 120.0°C / 0.1°C
- Surface temp: -80.0 ... 250.0°C / 0.1°C
Accuracy:
- Air humidity: ± 0.1% FS ± 1 digit
- Temperature: ± 0.2% FS ± 1 digit
- Surface temp: ± 0.5% of rdg. ± 0.5°C |
 |
|
|
|
|
|
|
MH 3350
Digital hand held instrument for air humidity and temperature
Plug-in sensors
Measurement inputs:
(mini-DIN socket)
- Air humidity: capacitive sensor
- Temperature: Pt 1000 / 2 wire
- Surface temp: Type K (NiCr-Ni)
Measurement range / resolution:
- Air humidity: 0.0 ... 100% rH / 0.1% rH
- Temperature: -40.0 ... 120.0°C / 0.1°C
- Surface temp: -80.0 ... 250.0°C / 0.1°C
Accuracy:
- Air humidity: ± 0.1% FS ± 1 digit
- Temperature: ± 0.2% FS ± 1 digit
- Surface temp: ± 0.5% of rdg. ± 0.5°C |
 |
|
|
|
|
|
|
MH 3110 / MH 3150
Digital hand held instrument for pressure
Plug-in sensors
Measurement inputs:
(mini-DIN socket)
- 1 x exchangeable pressure sensor MSD
Pressure types:
- Over, low, difference, absolute pressure, air pressure/barometer, vacuum measurement (sensor dependen)
Measurement range / resolution:
- -1999 ... 9999 digit / sensor dependent
Accuracy:
- ± 0.1% FS ± 1 digit |
 |
|
|
|
|
|
|
MH 3155
Digital hand held instrument for pressure
Plug-in sensors
Measurement inputs:
(mini-DIN socket)
- 2 x exchangeable pressure sensor MSD
Pressure types:
- Over, low, difference, absolute pressure, air pressure/barometer, vacuum measurement (sensor dependent)
Accuracy:
- ± 0.1% FS ± 1 digit |
 |
|
|
|
|
|
|
MH 3160 / MH 3180
Digital hand held instrument for prssure
internel piezoresisitive sensor
Pressure input: (6mm fitting)
- for air and non-corrosive / ionizing gases and liquids
Pressure types:
- Over, low, difference, absolute pressure, air pressure/barometer, vaccum measurement (sensor dependent)
Measurement range / resolution:
- 1999 ... 9999 digit / sensor dependent
Accuracy:
- ± 0.2% FS ± 1 digit |
 |
|
|
|
|
|
|
MH 1150
Digital hand held instrument for temperature
Plug-in sensors
Measurement inputs:
(mini-DIN socket)
- 1 x Type K (NiCr-Ni)
Measurement range / resolution:
- Type K: -50 ... 1150°C / 1°C
Accuracy:
- Type K: ± 1% of rdg. ± 1 digit |
 |
|
|
|
|
|
|
MH 175
Digital hand held instrument for temperature
Plug-in sensors
Measurement inputs:
(mini-DIN socket)
- 1 x Pt 1000 / 2 wire
Measurement range / resolution:
- Pt 1000: -70.0 ... 199.9°C / 0.1°C
Accuracy:
- Pt 1000: ± 0.1% of rdg. ± 1 digit |
 |
|
|
|
|
|
|
MH 2000
Digital hand held instrument for temperature
Plug-in sensors
Measurement inputs:
(mini-DIN socket)
- 1 x Pt 1000 / 4 wire
Measurement range / resolution:
- Pt 100: -199.9 ... 650.0°C / 0.1°C
Accuracy:
- Pt 100: ± 0.03% FS ± 1 digit |
 |
|
|
|
|
|
|
MH 3230 / MH 3250
Digital hand held instrument for temperature
Plug-in sensors
Measurement inputs:
(mini-TC socket)
- 2 x Type K, J, N, S, T
Measurement range / resolution:
- Type K: -199.9 ... 999.9°C / 0.1°C
or: -220 ... 1370°C / 1°C
- Type J: -120.0 ... 199.9°C / 0.1°C
or: -200 ... 1100°C / 1°C
- Type N: -199.9 ... 999.9°C / 0.1°C
or: -200 ... 1300°C / 1°C
- Type S: 0.0 ... 999.9°C / 0.1°C
or: -50 ... 1750°C / 1°C
- Type T: -120.0 ... 400.0°C / 0.1°C
or: -200 ... 400°C / 1°C
Accuracy:
- Type K: ± 0.08% of rdg. ± 0.1% FS ± 1 digit
- Type J: ± 0.2% of rdg. ± 0.1% FS ± 1 digit
- Type N: ± 0.2% of rdg. ± 0.1% FS ± 1 digit
- Type S: ± 0.1% of rdg. ± 0.1% FS ± 1 digit
- Type T: ± 0.2% of rdg. ± 0.1% FS ± 1 digit |
 |
|
|
|
|
|
|
SIKA Infrared Temperature Hand Held Measurement Devices
Targeting - Measuring - Reading
Remote Temperature Measurement
When it comes to temperature measurement technique and a combination of simplest control and high measurement accuracy is required, then infrared - thermometers will always be the first choice. This choice becomes a must, if one of the following requirements are given:
- Deterioration-free measurement
of moving components
- Measurement of dangerous matter
( e.g. electrically life parts, chemically
aggressive materials etc. )
- Measurement in inaccessible locations
- Feedback-free measurement of small
low-mass components
without infrared - thermometers is almost unthinkable.
In this case, nothing is easier as operation according to the motto:
targeting - measuring - reading the measurement value. |
 |
|
|
|
|
|
|
Remote Temperatur Measurement
Infrared Temperatur Measurement Devices MiniTemp 24
Measuring range
- -18 ... 275°C
Optical resolution
- 8/1 ( distance / spot )
Resolution
- 0,5°C or 1°F
Accuracy
- ± 2% of reading or ± 3°C |
 |
|
|
|
|
|
|
Remote Temperature Measurement
Infrared Temperature Measurement Devices SemiTemp 2030
Measuring range
- -32 ... 535 °C
Optical resolution
- 16/1 ( distance / spot )
Resolution
- 0,2°C
Accuracy
- ± 1% of reading or ± 3 °C |
 |
|
|
|
|
|
|
Remote Temperature Measurement
Infrared Temperature Measurement Devices SemiTemp 6080
Measuring range
- -32 ... 600°C
- -32 ... 760°C
Optical resolution
- 30/1 ( distance / spot )
- 50/1 ( distance / spot )
Resolution
- 0,1°C
Accuracy
- ± 1% of reading or ± 3°C |
 |
|
|
|
|
|
|
Remote Temperature Measurement
Infrared Temperature Measurement Devices MaxiTemp 24
Measuring range
- -30 ... 900°C
Optical resolution
- 60/1 ( distance / spot )
Resolution
- 0,1°C
Accuracy
- ± 1% of reading or ± 2°C |
 |
| |
|
|
|